Current Transducer HLSR-SM/SP33 series IPN = 10 ... 50 A
Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33,
HLSR 50-SM/SP33
For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation
between the primary and the secondary circuit.
Features
Applications
●● Open loop multi-range current transducer
●● AC variable speed and servo motor drives
●● Voltage output
●● Static converters for DC motor drives
●● Galvanic separation between primary and secondary
●● Battery supplied applications
●● Low power consumption
●● Uninterruptible Power Supplies (UPS)
●● Compact design for surface mount PCB mounting
●● Switched Mode Power Supplies (SMPS)
●● Factory calibrated
●● Power supplies for welding applications
●● High bandwidth, very low loss magnetic core.
●● Combiner box
●● MPPT.
Special feature
Standards
●● Single supply +3.3 V.
●● EN 50178: 1997
Advantages
●● Extremely low profile: h = 12 mm
●● Low foot-print
●● IEC 61010-1: 2010
●● IEC 61326-1: 2012
●● UL 508: 2010.
●● Low offset drift
Application Domain
●● Over-drivable Vref.
●● Industrial.
N°97.J4.13.033.0, N°97.J4.17.033.0, N°97.J4.J3.033.0, N°97.J4.23.033.0, N°97.J4.25.033.0
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 1/12
www.lem.com
HLSR-SM/SP33 series
Absolute maximum ratings
Parameter
Symbol
Unit
Value
Supply voltage (not destructive)
UC
V
8
Supply voltage (not entering non standard modes)
UC
V
6.5
Primary conductor temperature
TB
°C
120
UESD
kV
2
ESD rating, Human Body Model (HBM)
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may
degrade reliability.
UL 508: Ratings and assumptions of certification
File # E189713 Volume: 2 Section: 5
Standards
●● CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01
●● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15
Ratings
Parameter
Symbol
Primary involved potential
Unit
Value
V AC/DC
600
Max surrounding air temperature
TA
°C
105
Primary current
IP
A
According to series primary
current
Secondary supply voltage
UC
V DC
5
Output voltage
Vout
V
0 to 5
Conditions of acceptability
1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment.
2 - A suitable enclosure shall be provided in the end-use application.
3 - The terminals have not been evaluated for field wiring.
4 - These devices are intended to be mounted on a printed wiring board of end use equipment. The suitability of the
connections (including spacings) shall be determined in the end-use application.
5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals.
6 - Any surface of polymeric housing have not been evaluated as insulating barrier.
7-L
ow voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator,
limiting impedance or electro-mechanical relay).
Marking
Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
Page 2/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Insulation coordination
Parameter
Symbol
Unit
Value
Rms voltage for AC insulation test 50/60 Hz/1 min
Ud
kV
4.3
Impulse withstand voltage 1.2/50 µs
ÛW
kV
8
Clearance (pri. - sec.)
dCI
mm
>8
Shortest distance through
air
Creepage distance (pri. - sec.)
dCp
mm
>8
Shortest path along device
body
Clearance (pri. - sec.)
-
mm
8
When mounted on PCB
with recommended layout
Case material
-
-
V0
Comparative tracking index
Comment
According to UL 94
600
CTI
Application example
-
-
600 V CAT III
PD2
Reinforced insulation, non
uniform field according to
EN 50178, IEC 61010
Application example
-
-
1000 V
CAT III PD2
Simple insulation, non
uniform field according to
EN 50178, IEC 61010
Application example
-
-
600 V CAT III
PD2
Symbol
Unit
Min
Ambient operating temperature
TA
°C
−40
105
Ambient storage temperature
TS
°C
−40
105
Mass
m
g
According to UL 508
Environmental and mechanical characteristics
Parameter
Typ
Max
Comment
5
Page 3/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Electrical data HLSR 10-SM/SP33
At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9).
Parameter
Symbol
Unit
Primary nominal rms current
IPN
A
Primary current, measuring range
IPM
A
Number of primary turns
NP
-
1
Resistance of primary jumper @ TA = 25 °C
RP
mΩ
0.21
Resistance of primary jumper @ TA = 105 °C
RP
mΩ
0.29
Supply voltage
UC
V
Current consumption
IC
mA
Reference voltage (output)
Vref
V
1.63
Reference voltage (input)
Vref
V
0.5
Vout − Vref
V
−1.15
Vref output resistance
Rref
Ω
130
Vout output resistance
Rout
Ω
Capacitive loading
CL
nF
0
6
Electrical offset voltage @ IP = 0
VOE
mV
−5
5
Electrical offset current referred to primary
IOE
mA
−109
109
Temperature coefficient of Vref
TCVref
ppm/K
−150
150
Temperature coefficient of VOE
TCVOE
mV/K
−0.075
0.075
Temperature coefficient of IOE
TCIOE
mA/K
−1.63
1.63
Theoretical sensitivity
Gth
mV/A
Sensitivity error
εG
%
−0.5
0.5
Output voltage range @ IPM
Temperature coefficient of G
Min
Typ
Max
10
−25
3.135
25
3.3
3.465
19
25
1.65
1.67
Internal reference
1.7
External reference
1.15
Over operating
temperature range
200
300
series
2
5
series
ppm/K
−200
200
εL
% of IPN
−0.5
0.5
Linearity error 0 … IPM
εL
% of IPM
−0.8
0.8
Magnetic offset current
(@ 10 × IPN) referred to primary
IOM
A
−0.25
0.25
Reaction time @ 10 % of IPN
tra
µs
tr
µs
BW
kHz
Output rms voltage noise spectral density
100 Hz … 100 kHz
eno
µV/√ Hz
Output voltage noise
DC … 10 kHz
DC … 100 kHz
DC … 1 MHz
Vno
mVpp
Accuracy @ IPN
Vout − Vref
−40 °C … 105 °C
460 mV @ IPN
46
TCG
Frequency bandwidth (−3 dB)
For UC = 3.3 V ±5 %
T jumper = 120 °C
Linearity error 0 … IPN
Response time @ 90 % of IPN
Comment
Factory adjustment
2
@ 50 A/µs
2.5
@ 50 A/µs
450
16
9
22
40
X
% of IPN
−1
1
Accuracy @ IPN @ TA = +85 °C
X85 °C
% of IPN
−3.2
3.2
See formula note 1)
Accuracy @ IPN @ TA = +105 °C
X105 °C
% of IPN
−3.9
3.9
See formula note 1)
Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG
10000
× (TA –25) +
TCIOE
1000 × IPN
× 100 × (TA –25)).
Page 4/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Electrical data HLSR 20-SM/SP33
At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9).
Parameter
Symbol
Unit
Min
Primary nominal rms current
IPN
A
Primary current, measuring range
IPM
A
Number of primary turns
NP
-
1
Resistance of primary jumper @ TA = 25 °C
RP
mΩ
0.21
Resistance of primary jumper @ TA = 105 °C
RP
mΩ
0.29
Supply voltage
UC
V
Current consumption
IC
mA
Reference voltage (output)
Vref
Reference voltage (input)
Typ
Max
Comment
20
−50
50
For UC = 3.3 V ±5 %
T jumper = 120 °C
3.135
3.3
19
25
V
1.63
1.65
1.67
Internal reference
Vref
V
0.5
1.7
External reference
Vout − Vref
V
−1.15
1.15
Over operating
temperature range
Vref output resistance
Rref
Ω
130
200
300
series
Vout output resistance
Rout
Ω
2
5
series
Capacitive loading
CL
nF
0
6
Electrical offset voltage @ IP = 0
VOE
mV
−5
5
Output voltage range @ IPM
3.465
IOE
mA
−217
217
Temperature coefficient of Vref
TCVref
ppm/K
−150
150
Temperature coefficient of VOE
TCVOE
mV/K
−0.075
0.075
Temperature coefficient of IOE
TCIOE
mA/K
−3.26
3.26
Gth
mV/A
Electrical offset current referred to primary
Theoretical sensitivity
Sensitivity error
−40 °C … 105 °C
460 mV @ IPN
23
εG
%
−0.5
0.5
TCG
ppm/K
−200
200
Linearity error 0 … IPN
εL
% of IPN
−0.5
0.5
Linearity error 0 … IPM
εL
% of IPM
−0.8
0.8
Magnetic offset current
(@ 10 × IPN) referred to primary
IOM
A
−0.25
0.25
Reaction time @ 10 % of IPN
tra
µs
Temperature coefficient of G
Vout − Vref
Factory adjustment
2
@ 50 A/µs
2.5
@ 50 A/µs
Response time @ 90 % of IPN
tr
µs
Frequency bandwidth (−3 dB)
BW
kHz
Output rms voltage noise spectral density
100 Hz … 100 kHz
eno
µV/√ Hz
Output voltage noise
DC … 10 kHz
DC … 100 kHz
DC … 1 MHz
Vno
mVpp
X
% of IPN
−1
1
Accuracy @ IPN @ TA = +85 °C
X85 °C
% of IPN
−3.2
3.2
See formula note 1)
Accuracy @ IPN @ TA = +105 °C
X105 °C
% of IPN
−3.9
3.9
See formula note 1)
Accuracy @ IPN
Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG
10000
× (TA –25) +
TCIOE
1000 × IPN
450
8
6
13
23
× 100 × (TA –25)).
Page 5/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Electrical data HLSR 32-SM/SP33
At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9).
Parameter
Symbol
Unit
Primary nominal rms current
IPN
A
Primary current, measuring range
IPM
A
Number of primary turns
NP
-
1
Resistance of primary jumper @ TA = 25 °C
RP
mΩ
0.21
Resistance of primary jumper @ TA = 105 °C
RP
mΩ
0.29
Supply voltage
UC
V
Current consumption
IC
mA
Reference voltage (output)
Vref
V
1.63
Reference voltage (input)
Vref
V
0.5
Vout − Vref
V
−1.15
Vref output resistance
Rref
Ω
130
Vout output resistance
Rout
Ω
Capacitive loading
CL
nF
0
6
Electrical offset voltage @ IP = 0
VOE
mV
−5
5
Electrical offset current referred to primary
IOE
mA
−348
348
Temperature coefficient of Vref
TCVref
ppm/K
−150
150
Temperature coefficient of VOE
TCVOE
mV/K
−0.075
0.075
Temperature coefficient of IOE
TCIOE
mA/K
−5.22
5.22
Theoretical sensitivity
Gth
mV/A
Sensitivity error
εG
%
−0.5
0.5
Output voltage range @ IPM
Temperature coefficient of G
Min
Typ
Max
32
-80
3.135
80
3.3
3.465
19
25
1.65
1.67
Internal reference
1.7
External reference
1.15
Over operating
temperature range
200
300
series
2
5
series
ppm/K
−200
200
εL
% of IPN
−0.5
0.5
Linearity error 0 … IPM
εL
% of IPM
−0.8
0.8
Magnetic offset current
(@ 10 × IPN) referred to primary
IOM
A
−0.25
0.25
Reaction time @ 10 % of IPN
tra
µs
tr
µs
BW
kHz
Output rms voltage noise spectral density
100 Hz … 100 kHz
eno
µV/√ Hz
Output voltage noise
DC … 10 kHz
DC … 100 kHz
DC … 1 MHz
Vno
mVpp
Accuracy @ IPN
Vout − Vref
−40 °C … 105 °C
460 mV @ IPN
14.375
TCG
Frequency bandwidth (−3 dB)
For UC = 3.3 V ±5 %
T jumper = 120 °C
Linearity error 0 … IPN
Response time @ 90 % of IPN
Comment
Factory adjustment
2
@ 50 A/µs
2.5
@ 50 A/µs
450
5
4
10
16
X
% of IPN
−1
1
Accuracy @ IPN @ TA = +85 °C
X85 °C
% of IPN
−3.2
3.2
See formula note 1)
Accuracy @ IPN @ TA = +105 °C
X105 °C
% of IPN
−3.9
3.9
See formula note 1)
Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG
10000
× (TA –25) +
TCIOE
1000 × IPN
× 100 × (TA –25)).
Page 6/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Electrical data HLSR 40-SM/SP33
At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9).
Parameter
Symbol
Unit
Primary nominal rms current
IPN
A
Primary current, measuring range
IPM
A
Number of primary turns
NP
-
1
Resistance of primary jumper @ TA = 25 °C
RP
mΩ
0.21
Resistance of primary jumper @ TA = 105 °C
RP
mΩ
0.29
Supply voltage
UC
V
Current consumption
IC
mA
Reference voltage (output)
Vref
V
1.63
Reference voltage (input)
Vref
V
0.5
Vout − Vref
V
−1.15
Vref output resistance
Rref
Ω
130
Vout output resistance
Rout
Ω
Capacitive loading
CL
nF
0
6
Electrical offset voltage @ IP = 0
VOE
mV
−5
5
Electrical offset current referred to primary
IOE
mA
−435
435
Temperature coefficient of Vref
TCVref
ppm/K
−150
150
Temperature coefficient of VOE
TCVOE
mV/K
−0.075
0.075
Temperature coefficient of IOE
TCIOE
mA/K
−6.52
6.52
Theoretical sensitivity
Gth
mV/A
Sensitivity error
εG
%
−0.5
0.5
TCG
ppm/K
−200
200
Linearity error 0 … IPN
εL
% of IPN
−0.5
0.5
Linearity error 0 … IPM
εL
% of IPM
−0.8
0.8
Magnetic offset current
(@ 10 × IPN) referred to primary
IOM
A
−0.25
0.25
Reaction time @ 10 % of IPN
tra
µs
2
@ 50 A/µs
Response time @ 90 % of IPN
tr
µs
2.5
@ 50 A/µs
Frequency bandwidth (−3 dB)
BW
kHz
Output rms voltage noise spectral density
100 Hz … 100 kHz
eno
µV/√ Hz
Output voltage noise
DC … 10 kHz
DC … 100 kHz
DC … 1 MHz
Vno
mVpp
X
% of IPN
−1
1
Accuracy @ IPN @ TA = +85 °C
X85 °C
% of IPN
−3.2
3.2
See formula note 1)
Accuracy @ IPN @ TA = +105 °C
X105 °C
% of IPN
−3.9
3.9
See formula note 1)
Output voltage range @ IPM
Temperature coefficient of G
Accuracy @ IPN
Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG
10000
× (TA –25) +
TCIOE
1000 × IPN
Min
Typ
Max
Comment
40
−100
3.135
100
For UC = 3.3 V ±5 %
T jumper = 120 °C
3.3
3.465
19
25
1.65
1.67
Internal reference
1.7
External reference
1.15
Over operating
temperature range
200
300
series
2
5
series
Vout − Vref
−40 °C … 105 °C
460 mV @ IPN
11.5
Factory adjustment
450
4.5
4
9
14
× 100 × (TA –25)).
Page 7/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Electrical data HLSR 50-SM/SP33
At TA = 25 °C, UC = +3.3 V, RL = 10 kΩ unless otherwise noted (see Min, Max, typ. definition paragraph in page 9).
Parameter
Symbol
Unit
Primary nominal rms current
IPN
A
Primary current, measuring range
IPM
A
Number of primary turns
NP
-
1
Resistance of primary jumper @ TA = 25 °C
RP
mΩ
0.21
Resistance of primary jumper @ TA = 105 °C
RP
mΩ
0.29
Supply voltage
UC
V
Current consumption
IC
mA
Reference voltage (output)
Vref
V
1.63
Reference voltage (input)
Vref
V
0.5
Vout − Vref
V
−1.15
Vref output resistance
Rref
Ω
130
Vout output resistance
Rout
Ω
Capacitive loading
CL
nF
0
6
Electrical offset voltage @ IP = 0
VOE
mV
−5
5
Electrical offset current referred to primary
IOE
mA
−543
543
Temperature coefficient of Vref
TCVref
ppm/K
−150
150
Temperature coefficient of VOE
TCVOE
mV/K
−0.075
0.075
Temperature coefficient of IOE
TCIOE
mA/K
−8.15
8.15
Theoretical sensitivity
Gth
mV/A
Sensitivity error
εG
%
−0.5
0.5
Output voltage range @ IPM
Temperature coefficient of G
Min
Typ
Max
50
−125
3.135
125
3.3
3.465
19
25
1.65
1.67
Internal reference
1.7
External reference
1.15
Over operating
temperature range
200
300
series
2
5
series
ppm/K
−200
200
εL
% of IPN
−0.5
0.5
Linearity error 0 … IPM
εL
% of IPM
−0.8
0.8
Magnetic offset current
(@ 10 × IPN) referred to primary
IOM
A
−0.25
0.25
Reaction time @ 10 % of IPN
tra
µs
tr
µs
BW
kHz
Output rms voltage noise spectral density
100 Hz … 100 kHz
eno
µV/√ Hz
Output voltage noise
DC … 10 kHz
DC … 100 kHz
DC … 1 MHz
Vno
mVpp
Accuracy @ IPN
Vout − Vref
−40 °C … 105 °C
460 mV @ IPN
9.2
TCG
Response time @ 90 % of IPN
For UC = 3.3 V ±5 %
T jumper = 120 °C
Linearity error 0 … IPN
Frequency bandwidth (−3 dB)
Comment
Factory adjustment
2
@ 50 A/µs
2.5
@ 50 A/µs
450
4
3.3
7.3
12
X
% of IPN
−1
1
Accuracy @ IPN @ TA = +85 °C
X85 °C
% of IPN
−3.2
3.2
See formula note 1)
Accuracy @ IPN @ TA = +105 °C
X105 °C
% of IPN
−3.9
3.9
See formula note 1)
Note: 1) Accuracy @ TA (% of IPN) = X + ( TCG
10000
× (TA –25) +
TCIOE
1000 × IPN
× 100 × (TA –25)).
Page 8/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Maximum continuous DC current
60
50
40
IP (A)
HLSR 10-SM/SP33
HLSR 20-SM/SP33
HLSR 32-SM/SP33
HLSR 40-SM/SP33
HLSR 50-SM/SP33
30
20
10
0
-40
-20
0
20
40
60
80
100
120
140
TA (°C)
Important notice: whatever the usage and/or application, the transducer jumper temperature shall not go above the maximum
ratings of 120 °C as stated in page 2 of this datasheet.
Definition of typical, minimum and maximum values
Minimum and maximum values for specified limiting and safety conditions have to be understood as such as well as values shown
in “typical” graphs.
On the other hand, measured values are part of a statistical distribution that can be specified by an interval with upper and lower
limits and a probability for measured values to lie within this interval.
Unless otherwise stated (e.g. “100 % tested”), the LEM definition for such intervals designated with “min” and “max” is that the
probability for values of samples to lie in this interval is 99.73 %.
For a normal (Gaussian) distribution, this corresponds to an interval between −3 sigma and +3 sigma. If “typical” values are not
obviously mean or average values, those values are defined to delimit intervals with a probability of 68.27 %, corresponding to an
interval between −sigma and +sigma for a normal distribution.
Typical, minimum and maximum values are determined during the initial characterization of the product.
Page 9/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Measuring range versus external reference voltage
HLSR 10-xx/SP33
HLSR 20-xx/SP33
75
150
125
Uc = 3.3 V
Uc = 3.14 V
Uc = 2 .9 7 V
IP (A)
25
0
100
Uc = 3.3 V
Uc = 3.14 V
Uc = 2.97 V
75
50
IP (A)
50
25
0
-25
-25
-50
-50
-100
-75
-125
-150
-75
0.5
0.7
0.9
1.1
Vref (V)
1.3
1.5
0.7
0.9
1.1
Vref (V)
1.3
1.5
1.7
HLSR 40-xx/SP33
HLSR 32-xx/SP33
150
150
125
75
100
75
50
IP (A)
50
25
0
-25
Uc = 3.3 V
Uc = 3.14 V
Uc = 2.97 V
125
Uc = 3.3 V
Uc = 3.14 V
Uc = 2.97 V
100
IP (A)
0.5
1.7
25
0
-25
-50
-50
-75
-75
-100
-100
-125
-125
-150
-150
0.5
0.7
0.9
1.1
Vref (V)
1.3
1.5
0.5
1.7
0.7
0.9
1.1
Vref (V)
1.3
1.5
1.7
HLSR 50-xx/SP33
150
Uc = 3.3 V
Uc = 3.14 V
Uc = 2.97 V
125
100
75
IP (A)
50
25
0
-25
-50
-75
-100
-125
-150
0.5
0.7
0.9
1.1
Vref (V)
1.3
1.5
1.7
Page 10/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
PCB footprint (in mm. General linear tolerance ±0.2 mm)
dCI
dCp
Assembly on PCB
●● Pb free profile
●● No clean process only
Safety
This transducer must be used in limited-energy secondary circuits according to IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in
accordance with the manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.This transducer is a build-in device, whose conducting parts
must be inaccessible after installation.A protective housing or additional shield could be used.Main supply must be able to be
disconnected.
Page 11/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
HLSR-SM/SP33 series
Dimensions (in mm. General linear tolerance ±0.2 mm)
Connection
Uc
V out
V ref
IP
Remarks
●● Vout is positive with respect to Vref when positive IP flows in direction of the arrow shown on the drawing above
●● Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM Transducer Generic
Mounting Rules. Please refer to LEM document N°ANE120504 available on our Web site: Products/Product Documentation.
Page 12/12
7September2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com